Sản phẩm / Hygiene Advance™ Baffle C3
Hygiene Advance™ Baffle C3
Hệ thống
| Size,mm | |||||||
| 1200x600 | |||||||
| T15 | |||||||
| T24 | |||||||
| Thinkness | 20 | ||||||
| Mã 86. | |||||||
Chi tiết :
ystem and product description
| Ecophon Hygiene Advance Baffle C3 is an open system with vertical baffles intended for use in environment where there is a high level of contamination, and where frequent cleaning is required. This system is used mainly in premises where it is not possible to install a wall to wall ceiling because of sprinkler systems, installations or skylights, etc. Examples of applications: areas with high levels of airborne grease, areas exposed to spatter from meat juices, fruit juices or other liquids. The system consists of Ecophon Hygiene Advance Baffles, which have a core of high density glass wool encapsulated in a smooth high-performance film that is impervious to particles and water. The film is also dirt-repellent and resistant to most chemicals. The supporting structure is a cor |
Acoustics
![]() |
Acoustic: |
![]() |
Sound Absorption: Test results according to EN ISO 354. Classification according to EN ISO 11654. |
![]() |
Sound Insulation: Not applicable. |
![]() |
Sound Privacy: Not applicable |
| product | Hygiene Advance Baffle C3 in rows, c 600 mm, with ~1,4 baffles per m² of ceiling area | Hygiene Advance Baffle C3 in chequered pattern, with ~1,3 baffles per m² of ceiling area |
| o.d.s mm | - | - |
| absorption class | D | C |
| NRC | ||
| SAA |
259
Quantity specification (excl. wastage)
Installation diagram (M259) for Ecophon Hygiene Advance Baffle C3 (in rows)
Installation diagram (M259) for Ecophon Hygiene Advance Baffle C3 (in rows)
| Size, mm | |
| 1200x600 | |
| 1 Ecophon Hygiene Advance Baffle | 1,4/m² |
| 2 Connect T24 Main runner C3, installed at 600 mm centres | 1,7m/m² |
| 3 Connect T24 Cross tee C3, L=600 mm, installed at 1800 mm centres | 0,6m/m² |
| 4 Connect Adjustable hanger C3 | 1,4/m² |
| 5 Connect Hanger clip | 1,4/m² |
| 6 Connect Baffle clip C3 | 2,8/m² |
Technical properties
![]() |
Accessibility: The panels are demountable. |
![]() |
Cleanability: Daily dusting, vacuum cleaning, manual wet cleaning and high-pressure washing. Water temperature max. 70°C. Can withstand the use of common disinfecting chemicals. |
![]() |
Visual appearance: White 141, nearest NCS colour sample S 1000-N, 73% light reflectance. Please note: There is a small difference in gloss between the Hygiene Advance tile and the Hygiene Advance perimeter tile. |
![]() |
Influence of climate: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611). A higher temperature/moisture is permissible during washing as stated above. |
![]() |
Indoor Climate: Can be used in rooms classified as ISO class 5/M2.5. |
![]() |
Fire safety: The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. See Technical properties, Fire safety. |
| Country | Class | Standard |
| Europe | EN 13501-1 | A2-s1,d0 |
![]() |
Mechanical properties: For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties. |
![]() |
Installation: Installed according to system range. Cut tiles must be sealed with Connect Hygiene Advance Tape. |